| Basic Functions |
Frequency |
0.00Hz-400.00Hz |
| Carrier Frequency |
2.0-16.0KHz |
| Frequency Setting Resolution |
Analog setting: 0.1% of the highest frequency, Digital setting: 0.01Hz |
| Control Modes |
V/F control, Open-loop vectro control |
| Speed Stability |
±0.5% |
| Overload Capacity |
G-type machine: With reverse-time-limit overload protection, 115% for 6 minutes, 150% for 1 minute |
| V/F Curves |
Three modes: Linear, Quadratic, 1.5th power, 1.2nd power, User-defined V/F curve, V/F Separation |
| Acceleration Curve |
Linear mode |
| DC Braking |
DC brake start frequency: 0.00% - upper limit frequency, Brake time: 0.0-60.0s; Brake current: 0.0-100% of motor's rated current. |
| Jog Control |
Jog frequency range: 0.0Hz - maximum frequency, Jog acceleration/deceleration time: 0.1-999.9s |
| Simple PLC and Multi-segment Speed Running |
Up to 7 segments of speed running |
| Build-in PID |
Capable of implementing closed-loop control system for process control |
| Motor Parameter Identification |
Static identification |
| Overvoltage, Overcurrent, Stalling, and Over-Excitation Control |
Automatically limits current and voltage during operation, preventing frequent overcurrent, overvoltage, and trips |
| Torque Boost and Slip Compensation |
Torque boost can be selected as automatic or manual, Slip compensation enhances low-speed loaded capacity and compensates for slip speed |
| Communication Function |
Not available; SD320 has RS485 communication |
| Braking Function |
Not available; SD320 has braking function |
| Customizable Functions |
Oscillation Suppression |
Enables oscillation suppression to eliminate oscillations and prevent overcurrent in the inverter |
| PID Control |
Built-in PID controller for process control |
| Swing Frequency Function |
Outputs frequency, oscillating up and down around the set frequency, suitable for industries like textiles and chemical fibers |
| Operating Functions |
Upper and lower frequency setting, frequency hopping operation, reverse operation limitation, frequency increment and decrement control, fault auto-recovery operation, and more. |
| Constant Pressure Water Supply Function |
Maintains constant water pressure and automatically sleeps and wakes up based on pressure |
| SD321 Series: In addition to the features of SD320, the SD321 series offers the following optional functions: braking, RS485 Modbus communication, and temperature protection. |